General-purpose Relay
MY
An Improved Miniature Power Relay with
Many Models for Sequence Control and
Power Applications
A wide range of relay variations including ones with operation
indicators, built-in diodes, etc.
Arc barrier standard on 3- and 4-pole Relays.
Dielectric strength: 2,000 VAC.
LR
Ordering Information
List of Models
Type
Contact form
Plug-in socket/solder terminals
PCB terminals
Upper-mounting/
solder terminals
With indicator
Standard
DPDT
MY2
MY2N
MY2-02
MY2F
DPDT (bifurcated)
MY2Z
MY2ZN
MY2Z-02
MY2ZF
3PDT
MY3
MY3N
MY3-02
MY3F
4PDT
MY4
MY4N
MY4-02
MY4F
4PDT (bifurcated)
MY4Z
MY4ZN
MY4Z-02
MY4ZF
With built-in diode
DPDT
MY2-D
MY2N-D2
–––
–––
(DC only)
DPDT (bifurcated)
MY2Z-D
MY2ZN-D2
–––
–––
3PDT
MY3-D
MY3N-D2
–––
–––
4PDT
MY4-D
MY4N-D2
–––
–––
4PDT (bifurcated)
MY4Z-D
MY4ZN-D2
–––
–––
With built-in CR
DPDT
MY2-CR
MY2N-CR
–––
Not available.
(AC only)
DPDT (bifurcated)
MY2Z-CR
–––
–––
3PDT
MY3-CR
–––
–––
4PDT
MY4-CR
MY4N-CR
–––
4PDT (bifurcated)
MY4Z-CR
–––
–––
DPDT
MY2I4
MY2I4N
–––
–––
4PDT
MY4I4
MY4I4N
–––
–––
With test button
Note:
1. When ordering, add the rated coil voltage to the model number. Rated coil voltages are given in the coil ratings table.
Example: MY2, 6 VAC
Rated coil voltage
2. The standard contacts for MY2Z-series Relays and for the MY4Z are gold-plated.
1
MY
MY
Accessories (Order Separately)
Sockets
Poles
Front-mounting socket
Back-mounting socket
(DIN-rail/screw mounting)
Solder terminals
W/ clip
W/o clip
Wire-wrap terminals
W/ clip
PCB
W/o clip
terminals
2
PYF08A
PYF08A-E (finger protection)
PYF08A-N (finger protection)
PY08
PY08-Y1
PY08QN
PY08QN-Y1
PY08–02
3
PYF11A
PY11
PY11-Y1
PY11QN
PY11QN-Y1
PY11-02
4
PYF14A
PYF14A-N (finger protection)
PYF14A-E (finger protection)
PY14
PY14-3*
PY14-Y1
PY14QN
PY14QN-Y1
PY14-02
Note:
*1. Equipped with operation check terminal.
2. The PYF08A(-E), PYF11A, and PYF14A(-E) have been approved as individual sockets by UL S08 and CSA C22.2.
Mounting Plates for Sockets
Socket model
PY08, PY11, PY14, PY08QN(2),
PY11QN(2), PY14QN(2)
Note:
For 1 socket
PYP-1
For 18 sockets
For 36 sockets
PYP-18
PYP-36
PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of sockets.
Socket Hold-down Clip Pairing
Relay type
Poles
Front-connecting
sockets
(rail-/screw-mounted)
Socket
Standard, bifurcated contacts, operation
indicator, built-in diode.
Test button
CR circuit
2
Clip
PYC-A1
Back-connecting sockets
Solder/wire-wrap terminals
Socket
PYF08A-N,
PYF08A-E,
PYF08A
3
PYF11A
PY11(QN)
PY11(QN)
4
PYF14A-N,
PYF14A-E,
PYF14A
PY14(QN)
PY14(QN)
2
PYF08A-N,
PYF08A-E,
PYF08A
3
PYF11A
PY11(QN)
PY11(QN)
4
PYF14A-N,
PYF14A-E,
PYF14A
PY14(QN)
PY14(QN)
2
PYF08A-N,
PYF08A-E,
PYF08A
3
PYF11A
PY11(QN)
PY11(QN)
4
PYF14A-N,
PYF14A-E,
PYF14A
PY14(QN)
PY14(QN)
Y92H-3
PY08(QN)
PY08(QN)
PYC-P
PCB terminals
Socket
2
PYC-A1
PY08(QN)
Clip
PYC-P2
PYC-1
PY08(QN)
PY08(QN)
PY08(QN)
Clip
PYC-P
PYC-P2
PYC-1
MY
MY
Specifications
Coil Ratings
Rated voltage
Rated current
50 Hz
AC
DC
Coil
resistance
es sta ce
60 Hz
Inductance
(reference value)
Arm.
OFF
Must
operate
Arm. ON
Must
release
Max.
voltage
% of rated voltage
6V
214.1 mA
183 mA
12.2 :
0.04 H
0.08 H
80%
30%
12 V
106.5 mA
91 mA
46 :
0.17 H
0.33 H
max.
min.
24 V
53.8 mA
46 mA
180 :
0.69 H
1.30 H
50 V
25.7 mA
22 mA
788 :
3.22 H
5.66 H
100/110 V
11.7/12.9 mA
10/11 mA
3,750 :
14.54 H
24.6 H
110/120 V
9.9/10.8 mA
8.4/9.2 mA
4,430 :
19.20 H
32.1 H
200/220 V
6.2/6.8 mA
5.3/5.8 mA
12,950 :
54.75 H
94.07 H
220/240 V
4.8/5.3 mA
4.2/4.6 mA
18,790 :
83.50 H
136.40 H
6V
150 mA
40 :
0.17 H
0.33 H
10%
12 V
75 mA
160 :
0.73 H
1.37 H
min.
24 V
36.9 mA
650 :
3.20 H
5.72 H
48 V
18.5 mA
2,600 :
10.60 H
21.00 H
100/110 V
9.1/10 mA
11,000 :
45.60 H
86.20 H
110%
Power
consum.
co su
(A
)
(Approx.)
1.0 to
1 2 VA
1.2
(60 Hz)
0.9 to
1 1 VA
1.1
(60 Hz)
0.9 W
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23qC with tolerances of +15%/–20% for rated currents
and r15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperatures of 23qC.
3. AC coil resistance and impedance are provided as reference values (at 60 Hz).
4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder
resistor if required.
Contact Ratings
Item
Double- or three-pole
Resistive load
(cosf = 1)
Inductive load
(cosf=0.4,
L/R=7 ms)
2 A, 220 VAC
2 A, 24 VDC
Four-pole
Resistive load
(cosf = 1)
3 A, 220 VAC
3 A, 24 VDC
Inductive load
(cosf=0.4,
L/R=7 ms)
0.8 A, 220 V
1.5 A, 24 VDC
Rated load
5 A, 220 VAC
5 A, 24 VDC
Carry
current
5A
3A
Max.
switching
voltage
250 VAC
125 VDC
250 VAC
125 VDC
Max.
switching
current
5A
5A
3A
3A
Max.
switching
capacity
1,100 VA
120 W
440 VA
48 W
660 VA
72 W
176 VA
36 W
Min.
permissible
load*
Standard type: 100 mA, 5 VDC
Bifurcated type: 100 PA, 1 VDC
Standard type: 1
mA, 1 VDC
Bifurcated type: 100 PA, 1 VDC
*Note: P level: O60 = 0.1 x 10-6 /operation, reference value
3
MY
MY
Characteristics
Item
All relays
Contact resistance
50 m: max.
Operate time
20 ms max.
Release time
20 ms max.
Max. operating frequency
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance
1,000 M: min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min (1,000 VAC
between contacts of same polarity)
Vibration resistance
Destruction: 10 to 55 Hz, 1.0-mm double amplitude
Malfunction: 10 to 55 Hz, 1.0-mm double amplitude
Shock resistance
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 200 m/s2 (approx. 20G)
Life expectancy
See following table.
Ambient operating temperature*
Single- and double-pole standard, bifurcated-contact, test-button, relays:
–55qC to 70qC (with no icing)
All other relays: –55qC to 60qC (with no icing)
Ambient operating humidity
35% to 85%
Weight
Approx. 85 g
Note:
The values given above are initial values.
Life Expectancy Characteristics
Relays
Mechanical life
(at 18,000 operations/hr)
Electrical life
(at 1,800 operations/hr under rated load)
Normal, With test button (except relays with operation
indicator), With CR
AC 50,000,000 operations min.
DC: 100,000,000 operations min.
1-,2-,3-pole: 500,000 operations min.
4-pole:
200,000 operations min.
With operation indicator or built-in diode
AC 50,000,000 operations min.
DC: 100,000,000 operations min.
1-,2-,3-pole: 500,000 operations min.
4-pole:
200,000 operations min.
With bifurcated contacts
2-pole: 50,000,000 operations min.
4-pole:
2-pole: 200,000 operations min.
4-pole: 100,000 operations min.
Note:
See following tables for real load life expectancies.
Life Expectancies Under Real Loads
MY2
Rated voltage
100 VAC
Load type
AC motor
AC solenoid
Conditions
Operating frequency
Electrical life
50 W, 100 VAC single-phase with
2.8-A inrush current, 0.4-A carry
current
ON for 2 s, OFF for 30 s
100,000 operations
50 W, 100 VAC single-phase with
1.6-A inrush current, 1-A carry current
ON for 1 s, OFF for 30 s
300,000 operations
24 W with 1-A carry current
ON for 1.5 s, OFF for 1.5 s
4,000,000 operations
MY4
Rated voltage
100 VAC
24 VDC
4
Load type
Conditions
Operating frequency
ON for 1 s, OFF for 3 s
Electrical life
AC solenoid
50 VA with 2-A inrush current, 0.7A
carry current
25,000 operations
DC magnetic
switch
25 W with L/R = 40 ms , 0.2-A carry
current
AC magnetic
switch
35 VA with 1.5-A inrush current,
0.35-A carry current
DC solenoid
40 W with L/R = 10 ms, 1.6-A carry
current
ON for 0.5 s, OFF for 1.5 s
5,000,000 operations
30 W with L/R = 10 ms with 0.34-A
carry current
ON for 0.5 s, OFF for 1.5 s
6,000,000 operations
500,000 operations
MY
MY
Approved by Standards
Some MY Relays are available in models meeting various safety
standards. When ordering, you must specify the desired standards.
Refer to Ordering Information for specific models. Note that the rating recognized by the various standards sometimes vary from the
ratings of the individual relays.
UL 508 Recognitions (File No. 41515)
No. of poles
2
Coil ratings
6 to 240 VAC
6 to 125 VDC
3
Contact ratings
5 A, 120 VAC resistive load
5 A, 28 VDC resistive load
5 A, 240 VAC inductive load
LR (No. 563KOB-204524)
Model
MY -LR
No. of
poles
2
5 A, 28 VDC resistive load
5 A, 240 VAC inductive load
4
6 to 240 VAC
6 to 125 VDC
3 A 28 VDC resistive load
3 A 120 VAC inductive load
1.5 A, 240 VAC inductive load
5 A, 240 VAC inductive load
(between contacts of same
polarity)
5 A, 28 VDC resistive load
(between contacts of same
polarity)
0.2 A, 120 VDC
4
Coil
ratings
6 to 240
VAC
6 to 120
VDC
Contact ratings
2 A, 30 VDC inductive
load
2 A, 200 VAC inductive
load
1.5 A, 30 VDC
inductive load
0.8 A, 200 VAC
inductive load
1.5 A, 115 VAC
inductive load
CSA 22.2 No. 0 and No.14 (File No. LR31928)
Model
MY
No. of
poles
2, 3
Coil
ratings
6 to 240
VAC
6 to 120
VDC
4
Contact ratings
5 A, 28 VDC resistive
load
5 A, 240 VAC inductive
load
3 A, 28VDC resistive
load
3 A, 240 VAC inductive
load
5 A, 240 VAC inductive
load (between contacts
of same polarity)
5 A, 28 VDC resistive
load (between contacts
of same polarity)
0.2 A, 120 VDC
Engineering Data
Maximum Switching Capacity
Switching current (A)
MY2, MY3
AC resistive load
AC inductive load
(cosf = 0.4)
DC resistive
load
DC inductive
load (L/R = 7 ms)
Switching voltage (V)
5
MY
MY
MY4, MY4Z
AC resistive
load
Switching current (A)
AC inductive load
(cosf = 0.4)
DC resistive load
DC Inductive
load
L/R = 7 ms
Switching voltage (V)
Life Expectancy
5,000
110 VAC resistive load
220 VAC
resistive load
1,000
500
24 VDC resistive
load
100
MY2, MY3 (Inductive Loads)
Life expectancy (x103 operations)
Life expectancy (x103 operations)
MY2, MY3 (Resistive Loads)
5,000
110 VAC inductive
load (cosf = 0.4)
1,000
500
100
Switching current (A)
Switching current (A)
5,000
110 VAC resistive
load
220 VAC resistive load
1,000
500
30 VDC resistive
load
100
MY4 (Inductive Loads)
Life expectancy (x10 3 operations)
Life expectancy (x103 operations)
MY4 (Resistive Loads)
5,000
500
100
1,000
500
100
220 VAC resistive load
24 VDC resistive load
Switching current (A)
6
220 VAC Inductive
load
30 VDC Inductive
load
Switching current (A)
MY4Z (Inductive Loads)
Life expectancy (x103 operations)
Life expectancy (x103 operations)
5,000
110 VAC Inductive
load
1,000
Switching current (A)
MY4Z (Resistive Loads)
220 VAC inductive load
(cosf = 0.4)
24 VDC inductive load
(L/R = 7 ms)
5,000
1,000
500
110 VAC (cosf = 0.4)
24 VDC
L/R = 7 ms
100
220 VAC (cosf = 0.4)
Switching current (A)
MY
MY
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
Relays with Solder Terminals
MY2, MY2N, MY2N-D2
MY2N
Standard
2.6
DC type
AC type
Eight, 1.2 dia. x 2.2 ellipse holes
0.5
28 max.
6.3
0.5
36 max.
21.5
max.
6.4
Note:
1. AC type is equipped with a coil disconnection
self–diagnostic function.
2. Pay due attention as DC type has polarity.
MY2N-D2
MY3, MY3N, MY3N-D2,
MY3N
2.6
Standard
DC type
AC type
Eleven, 1.2 dia. x 2.2
ellipse holes
28 max.
6.3
0.5
36
max.
6.4
21.5
max.
Note:
1. AC type is equipped with a coil disconnection self–
diagnostic function.
2. Do not reverse the polarity of DC relays.
MY3N-D2
7
MY
MY
MY4
2.6
Fourteen, 1.2 dia. x 2.2
ellipse holes.
0.5
28 max.
6.3
0.5
36
max.
21.5
max.
6.4
Terminal arrangement/internal connections
(bottom view)
MY4N-D2
MY4N
Standard
Note:
DC type
AC type
1. AC type is equipped with a coil disconnection selfdiagnostic function.
2. Do not reverse the polarity of DC relays.
MY I4
2.6
3.3
20.3
Fourteen, 1.2 dia. x 2.2
ellipse holes
3 max.
Push button
28 max.
0.5
6.3
36
max.
Note:
Note:
8
6.4
21.5 max..
1. Mount the relay with a socket.
2. Test button
I4: AC with red push button
DC with blue push button
The terminal arrangement and internal connections of the above relays are as same as these of MY
relays.
MY
MY
MY (N)-CR, MY (Z)-CR
MY (N)-C
R
2.6
MY (Z)-C
R
Fourteen, 1.2 dia. x 2.2 ellipse holes
CR
CR
0.5
28 max.
6.3
0.5
53
max.
6.4
21.5
max.
Relays with PCB Terminals
MY -02
PC Board Mounting Holes
MY4-02 (4PDT)
3.5
1
3.3 (2.6)
DPDT
3PDT
13.2
13.2
4PDT
13.2
4.4
4.3
4.1
0.5
28 max.
6.3
0.5
36 max.
4
21.5
max.
6.35
12.65
6.3
3.75
Eight,
1.3r0.1
holes
Eleven,
1.3r0.1
holes
Fourteen,
1.3r0.1
holes
Note: The tolerance is r0.1.
Note: 1. The figures in the parentheses are for MY4-02.
2. The above dimensions also apply to the DPDT and
3PDT Relays.
3. The internal connections of the above Relays are as
same as these of MY@ Relays.
9
MY
MY
Upper-mounting Relays
MY F
Mounting holes
MY4F
2.6
Two 3.5 dia holes or M3 holes
Fourteen, 1.2 dia. x 2.2
ellipse holes
2
Note:
38
29 max.
0.5
0.5
36
max
.
4.35
38 44 max.
6.4
3.5
22.5 max.
1. The above dimensions also apply to the DPDT,
and 3PDT relays.
2. The internal connections of the above relays are as
same as these of MY relays.
Mounting Height with Socket
DIN Track/Surface-mounting Socket
Back-mounting Socket
MY
70 (87)
66 (83)
39 (56)
MY
PYF A(-E)
PY@
Note:
1. The PTF-A can be rail–mounted or screw-mounted.
2. For the MY -CR (CR circuit built-in type) model, figure
in the parentheses apply.
3. PYC-P hold down clip should be used with PYF08M.
10
MY
MY
Sockets
PYF08A-E
PYF08A-N
PYF08A
PY08
PY08-Y1
PY08QN
PY08-02
PYF14A-E
PYF14A-N
PY14
PY14-Y1
PY14QN(2)
PY14QN(2)-Y1
PY14-02
PYF11A
PY11
PY11QN(2)
PY11QN(2)-Y1
PY11-02
9
MY
MY
Mounting Plates for Sockets
PYP-1
PYP-18
PYP-36
72 wide ellipse
hole
27.4
r0.15
492
17 x 27.4 = 465.8 r 0.6
72 wide ellipse hole
21.6
27.4
r0.15
Two, 3.4 dia. holes
492
17 x 27.4 = 465.8 r 0.6
21.6
13.1
13.1
4.5
3.4
+0.2
21.4 0
R1.7
4.5
3.4
39.7r0.2
Square
hole
86.4
42
r0.1
42r0.1
49
49
39.7r0.2
+0.2
21.4 0
28
t = 1.6
13.1
t = 1.6
21.6
17 x 27.4 = 465.8 r 0.6
t = 1.6
Hold-down Clips
Hold-down clips are used to hold relays to sockets and prevent them from coming loose due to vibration or shock.
Connection to socket
PYC-A1
Connection to
mounting plate
PYC-P
PYC-S
PY14-3 (for 4PDT)
with operation check terminal
For relays with test
buttons
PYC–P2
For relays with CR circuits
Y92H-3
Mounting holes
81
56
28
9(7.7)
2
38.5
78 +0.3
–0
0.3 34.5+0.4
Operation check terminal
Operation checklamp can be built-in.
77.5 +0
–0.4
Three, 1.2 dia holes Two dia. holes Short-circuit lead wire
Safety Standards for Sockets
Item
Standards
File No.
PYF08A (-E), PYF11A
UL508
E87929
PYF14A (-E)
CSA22.2
LR31928
12
PYC-1
36 +0.3
–0
MY
MY
Precautions
Connections
Do not reverse polarity when connecting DC-operated relays with
built-in diodes or indicators DC-operated relays.
Mounting
t
Whenever possible, mount relays so that it is not subject to
vibration or shock in the same direction as that of contact
movement.
t
The test button should be be pointed upwards when mounting
(refer to the right figure).
Test button
13
Singapore Office:
OMRON ELECTRONICS PTE. LTD.
438A Alexandra Road, #05-05/08
(Lobby 2) Alexandra Technopark
Singapore 119967
Tel: (65) 6547 6789
Fax: (65) 6547 6769
E-mail: mktg_sg@ap.omron.com
Malaysia Office:
OMRON ELECTRONICS SDN. BHD.
1101 Level 11 Uptown 1
1 Jalan SS21/58 Damansara Uptown
47400 Petaling Jaya, Selangor
Malaysia
Tel: (60-3) 7688 2888
Fax: (60-3) 7688 2833
E-mail: my_enquiry@ap.omron.com
Thailand Office:
OMRON ELECTRONICS CO. LTD.
Rasa Tower 20th Floor
555 Phaholyothin Road
Chatuchak, Bangkok
10900, Thailand
Tel: (66-2) 937 0500
Fax: (66-2) 937 0501
CRM Call Centre: (66-2) 942 6700
E-mail: th_enquiry@ap.omron.com
Indonesia Office:
PT. OMRON ELECTRONICS
Graha Pratama Building, 3A Floor
Jl. M.T. Haryono Kav 15
Jakarta Selatan 12810
Indonesia
Tel: (62-21) 8370 9555
Fax: (62-21) 8370 9550
E-mail: id_enquiry@ap.omron.com
Philippines Office:
OMRON ASIA PACIFIC PTE. LTD.
MANILA REPRESENTATIVE OFFICE
2nd Floor, Kings Court II Building
2129 Do Chino Roces Avenue
Corner Dela Rosa Street
1231 Makati City, Metro Manila
Philippines
Tel: (63-2) 811 2831
Fax: (63-2) 811 2583
E-mail: ph_enquiry@ap.omron.com
Australia Offices:
Sydney Office:
OMRON ELECTRONICS PTY. LTD.
Omron House
71 Epping Road, North Ryde
Sydney, New South Wales 2113
Australia
Tel: (61-2) 9878 6377
Fax: (61-2) 9878 6981
Toll Free: 1800 678838
E-mail: au_enquiry@ap.omron.com
Melbourne Office:
OMRON ELECTRONICS PTY. LTD.
Axxess Corporate Park
Unit 98, 45 Gilby Road
Mt Waverley Victoria 3149
Australia
Tel: (61-3) 8588 2600
Fax: (61-3) 8588 2690
E-mail: au_enquiry@ap.omron.com
Brisbane Office:
OMRON ELECTRONICS PTY. LTD.
Unit 14, 1378 Lytton Road
Hemmant 4174, Queensland
Australia
Tel: (61-7) 3859 3900
Fax: (61-7) 3348 8701
E-mail: au_enquiry@ap.omron.com
Adelaide Office:
OMRON ELECTRONICS PTY. LTD.
Suite 12, 18 Humpheries Terrace
Kilkenny, SA 5009
Australia
Tel: (61-8) 8440 6412
Fax: (61-8) 8345 1204
E-mail: au_enquiry@ap.omron.com
New Zealand Office:
OMRON ELECTRONICS LTD.
65 Boston Road, Mt Eden
Private Bag 92620
Symonds Street, Auckland
New Zealand
Tel: (64-9) 358 4400
Fax: (64-9) 358 4411
E-mail: nz_enquiry@ap.omron.com
Asia Pacific Head Office:
India Offices:
Bangalore Office:
OMRON AUTOMATION PVT. LTD.
No. 43, G.N. Complex
St.Johns Road
Bangalore - 560 042
India
Tel: (91-80) 4072 6400/401
Fax: (91-80) 4146 6403
E-mail: in_enquiry@ap.omron.com
Noida Office:
OMRON AUTOMATION PVT. LTD.
212 & 213, 2nd Floor
International Home Deco Park (IHDP)
Plot No.7, Sector 127, Taj Express Way
Noida 201301
India
Tel: (91-120) 4745 800
Fax:(91-120) 4745 801
E-mail: newdelhi_enquiry@ap.omron.com
Mumbai Office:
OMRON AUTOMATION PVT. LTD.
102 & 103, Meadows, Sahar Plaza,
Andheri-Kurla Road, Andheri East
Mumbai - 400 059
India
Tel: (91-22) 4275 5600
Fax: (91-22) 4275 5602
E-mail: mumbai_enquiry@ap.omron.com
Vietnam Offices:
OMRON ASIA PACIFIC PTE. LTD.
HANOI REPRESENTATIVE OFFICE
6th Floor, 92 Hoang Ngan Street
Trung Hoa, Cau Giay
Hanoi, SR Vietnam
Tel: (84-4) 3556 3444
Fax: (84-4) 3556 3443
E-mail: hn_enquiry@ap.omron.com
HO CHI MINH REPRESENTATIVE OFFICE
99 Nguyen Thi Minh Khai Street
District 1, Ho Chi Minh City
SR Vietnam
Tel: (84-8) 3839 6666
Fax: (84-8) 3830 1279
E-mail: hcm_enquiry@ap.omron.com
Authorized Distributor
i
OMRON ASIA PACIFIC PTE. LTD.
438A Alexandra Road
#05-05/08
(Lobby 2) Alexandra Technopark
Singapore 119967
Tel: (65) 6835 3011 Fax: (65) 6835 2711
E-mail: ask@ap.omron.com
Website:
eb
www.omron-ap.com
.omr n
Cat. No. J01P-E-01
Singapore
0410
In the interest of product improvement, specifications are subject to change without notice.